-40%

Pyxis ST-600 Series Inline Disinfection + Temperature Sensors

$ 1400.25

Availability: 100 in stock
  • Brand: Undisclosed
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: Does not apply
  • Item must be returned within: 14 Days

    Description

    DESCRIPTION
    The Pyxis ST-600 series inline probes measure the real-time mass/mass concentration of Chlorine in Sodium Hypochlorite Bleach and Chlorine Dioxide (ClO2) in Solution. Unlike typical amperometric sensors for disinfection liquids in ppm level, the ST-600 series inline probes directly measure the optical density of the Bleach or Chlorine Dioxide solution in percentage level without dilution using a UV light source. The ST-600 series probes have a built-in reference light source and a reference light detector in addition to the main light source and main light detector. This configuration ensures a long-term stable measurement of the disinfectant concentration. These probes featuring an expanded detection range and an RTD temperature compensated output signal, allowing the user to measure higher concentrations of industrial Bleach / ClO2 respectively and to obtain a temperature measurement, useful when required to consider the impact of atmospheric temperature conditions on variable concentration readings. Typical Applications • Biocontrol for industrial water • Industrial Oxidizer Generation (ie. Hypochlorite /Monochloramine / ClO2) • Swimming pool and SPA • Hospital • Pulp & Paper
    T
    his part includes:
    ST-600 Series Inline Sensor
    Inline Tee (ST-001) for Piping Installations
    FEATURES
    Break-through technology measures disinfection liquids in high concentration
    Direct read technology without dilution or reagent.
    Long maintenance and calibration cycle – 6 months typical.
    Convenient ¾” NPT Inline Tee installation (ST-001) for Large Pump Suction Side
    Convenient ¼” Teflon Tubing Installation for Small Pump Discharge Side
    Probe Cleanliness Diagnostics via uPyxis and Modbus
    Wireless Calibration via uPyxis Mobile or Desktop APP
    Expanded concentration range
    Temperature Compensation (RTD) and Output Signal
    SPECIFICATIONS
    I
    t
    em
    S
    T
    -
    600
    S
    T
    -
    601
    S
    T
    -
    604
    Part Number
    50231
    50232
    50233
    Target
    % Chlorine in Bleach
    % ClO2 in Solution
    % Chlorine in Bleach
    Concentration Output Range (4-20mA)
    0-16% (mass/mass)
    0-0.35% mass/mass
    0% - 2% mass/mass
    Temperature Output Range (4-20mA)
    4mA – 0 °C / 32 °F 20mA - 100 °C / 212 °F
    Resolution
    0.01 in percentage
    Accuracy
    ±2% of reading or 0.1 percentage, whichever is greater
    Method
    UV Absorbance
    Power Supply
    22-26VDC, 2W
    Outputs
    Isolated 2x 4-20mA Analog
    Isolated RS-485 Modbus
    Dimension
    Length 6.8-inch, body diameter 1.44 inch
    Weight
    0.37 pounds
    Installation Formats
    ¼” OD (7 mm) Teflon tubing for measurement flow ST-001 Inline Tee ¾” CPVC
    Material
    UPVC
    Pressure
    Up to 100 psi (6.9 Bar)
    Temperature
    Operating: 4 °C – 50°C (40-120 °F) Storage: -7 °C - 60 °C (20 - 140 °F)
    Cable Length
    5 feet (Bulkhead Cable w/ IP67 Adapter – 7 pin) 1.5 foot (Flying Lead Cable w/IP67 Adapter – 7 pins
    Calibration
    Two-point calibration against standard solutions
    IP67
    Rating
    Regulation
    CE / RoHS