-40%
Pyxis ST-600 Series Inline Disinfection + Temperature Sensors
$ 1400.25
- Description
- Size Guide
Description
DESCRIPTIONThe Pyxis ST-600 series inline probes measure the real-time mass/mass concentration of Chlorine in Sodium Hypochlorite Bleach and Chlorine Dioxide (ClO2) in Solution. Unlike typical amperometric sensors for disinfection liquids in ppm level, the ST-600 series inline probes directly measure the optical density of the Bleach or Chlorine Dioxide solution in percentage level without dilution using a UV light source. The ST-600 series probes have a built-in reference light source and a reference light detector in addition to the main light source and main light detector. This configuration ensures a long-term stable measurement of the disinfectant concentration. These probes featuring an expanded detection range and an RTD temperature compensated output signal, allowing the user to measure higher concentrations of industrial Bleach / ClO2 respectively and to obtain a temperature measurement, useful when required to consider the impact of atmospheric temperature conditions on variable concentration readings. Typical Applications • Biocontrol for industrial water • Industrial Oxidizer Generation (ie. Hypochlorite /Monochloramine / ClO2) • Swimming pool and SPA • Hospital • Pulp & Paper
T
his part includes:
ST-600 Series Inline Sensor
Inline Tee (ST-001) for Piping Installations
FEATURES
Break-through technology measures disinfection liquids in high concentration
Direct read technology without dilution or reagent.
Long maintenance and calibration cycle – 6 months typical.
Convenient ¾” NPT Inline Tee installation (ST-001) for Large Pump Suction Side
Convenient ¼” Teflon Tubing Installation for Small Pump Discharge Side
Probe Cleanliness Diagnostics via uPyxis and Modbus
Wireless Calibration via uPyxis Mobile or Desktop APP
Expanded concentration range
Temperature Compensation (RTD) and Output Signal
SPECIFICATIONS
I
t
em
S
T
-
600
S
T
-
601
S
T
-
604
Part Number
50231
50232
50233
Target
% Chlorine in Bleach
% ClO2 in Solution
% Chlorine in Bleach
Concentration Output Range (4-20mA)
0-16% (mass/mass)
0-0.35% mass/mass
0% - 2% mass/mass
Temperature Output Range (4-20mA)
4mA – 0 °C / 32 °F 20mA - 100 °C / 212 °F
Resolution
0.01 in percentage
Accuracy
±2% of reading or 0.1 percentage, whichever is greater
Method
UV Absorbance
Power Supply
22-26VDC, 2W
Outputs
Isolated 2x 4-20mA Analog
Isolated RS-485 Modbus
Dimension
Length 6.8-inch, body diameter 1.44 inch
Weight
0.37 pounds
Installation Formats
¼” OD (7 mm) Teflon tubing for measurement flow ST-001 Inline Tee ¾” CPVC
Material
UPVC
Pressure
Up to 100 psi (6.9 Bar)
Temperature
Operating: 4 °C – 50°C (40-120 °F) Storage: -7 °C - 60 °C (20 - 140 °F)
Cable Length
5 feet (Bulkhead Cable w/ IP67 Adapter – 7 pin) 1.5 foot (Flying Lead Cable w/IP67 Adapter – 7 pins
Calibration
Two-point calibration against standard solutions
IP67
Rating
Regulation
CE / RoHS